Insufficient Capacity (Cont’d) Leaks in the vacuum piping (VCX) Check process piping for leaks. To confirm the leaks are in the piping, run the pum

Strona 3

Insufficient Capacity (Cont’d) Improperly operating relief valve (PCX) Check to see if air is coming out of the relief valve during normal operation

Strona 4

Operating Temperature too High (Cont’d)Insufficient clearance around pump If the clearance around the pump is too small, cooling air can not flow an

Strona 5

9.0 Safety 9.1Before repairs are attempted, be sure the power to the unit is off and locked out so accidental startup can not occur during repairs

Strona 6

14VCX 100/250/300

Strona 7

Pos. # Description Qty Pos. # Description Qty Pos. # Description Qty1 Gear Box Housing 1 53 Inner Box of Exhaust Silencer 1 100 Coupling, Pump Side 12

Strona 8

16VCX-500

Strona 9 - 8.0 Troubleshooting Chart

Pos. # Description Qty Pos. # Description Qty Pos. # Description Qty1 Gear Box Housing 1 50 Gasket, Exhaust Silencer 1 104 Cover Plate for fan 12 Gear

Strona 10

150 South Van Brunt St. Englewood, NJ 07631Tel: 1-888-222-9940Fax: [email protected] Newmarket ParkwayMarietta, GA 30067Tel: 770-

Strona 11

ROTARY CLAW VACUUM PUMPS AND COMPRESSORS Table of Contents Section: Page Number:1.0 Description 32.0 Application Range 33.0 Application Limits 44.0 C

Strona 12

1.0 Description The Airtech Vacuum, Inc. rotary claw vacuum pumps and compressors are dry, contactless machines. Two claws rotate in opposite direct

Strona 13

3.0 Application Limits The base machine design in standard configuration is for use on dry air only. Handling of humid air or gases containing aggre

Strona 14 - VCX 100/250/300

6.0 Installation and Start-up 6.1.1.1 Place the VCX or PCX rotary claw vacuum pump or compressor on a level surface. The splash lubrication system f

Strona 15

maintain the vacuum level desired by rotating the adjustment knob clockwise or counterclockwise, depending on adjustment desired. 6.2.1 For the PCX p

Strona 16

pulsation dampener can also reduce the amplitude of the pulsation to a point where it will not affect the piping or downstream processes. Contact yo

Strona 17

Table 7-1 Recommended Maintenance ItemsItem requiring Maintenance Interval What to check/do Inlet filter Monthly, more often if high particulates

Strona 18

8.0 Troubleshooting Chart Fault Probable Cause RemedyMotor Starter Trips Incorrect voltage lower than required. Check voltage at the motor and cor